Measure Setup of exclusive communication addresses
Recommendations • Only very specific computers may connect to the device.
• Only a very specific address range may communicate with the device within the
ne
wor
.
• When communicating, the device may only use specific protocols.
Pre-conditions Administrative access to the Command Center.
Notes • This page is linked to the menu "Basic/device security".
• A total of ten filters is available, that can be set independently of each other.
• After the settings are made, the network interfaces have to be re-initialized.
1 IP address
IP address of the computer with which the device is to communicate.
Depending on the definition of the subnet mask, the segment address that is entered determine the
kind of communication that is allowed with the device.
2 Subnet mask
Depending on the entry of the IP address, the subnet mask defines the area (segment) within which
communication with the device is possible.
3Protocols
The above settings are only applicable for the protocols that have been marked. Protocols that have not
been marked are excluded from the communication!
on
iguration example
IPv
:
IP address: 192.168.100.xxx (x=any)
Subnet mask: 255.255.255.0
All computers within the address area of the IP: 192.168.100.1 to IP: 192.168.100.255 may communicate
with the device (provided that at least one protocol has been marked).
All other computers are excluded from communicating.