KYOCERA FS-1300D User Manual Page 30

  • Download
  • Add to my manuals
  • Print
  • Page
    / 410
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 29
PRESCRIBE Command Reference
20
ALTB S — [ALlocate TaBle] Start to define the
combination character
Format
ALTB S, table-id, code[, width, height[[, x-coordinate, y-coordinate,
[paint-mode]]];
Parameters
table-id:
number identifying the character table to define the combination character, from 1 to
65535
code:
character code for which the combination character is defined. 1-byte code = 0 to 255;
2-byte code = 0 to 65533, or in hexadecimal notation ($xxxx).
width:
overall width of the combined character, represented by number from 1 to 65535 in units
where the width of the resident font character is 1000
height:
overall height of the combined character, represented by number from 1 to 65535 in units
where the height of the resident font character is 1000
x-coordinate:
X coordinate of the reference point, integer value converted in reference to 1000 units
y-coordinate:
Y coordinate of the reference point, integer value converted in reference to 1000 units
paint-mode:
paint mode: 0 = normal (filled), non-zero = line width of outline character (stroked):
1 to 100 units
Function
This command starts to define the combination of characters by specifying the region
and coordinates. The characters to combine in this region are registered using the
ALTB T command (page 21). The ALTB S sequence is terminated by the ALTB E
command. If the identical table number already exists, the existing character table is
replaced with the new character table.
Page view 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 409 410

Comments to this Manuals

No comments