Page view 67
Section 8 TROUBLESHOOTING
8-2
“E72” appears on the copy quantity/
magnification display
Originals for another job were set in the optional Document Processor
during copying from the platen in the 2-in-1 or 4-in-1 layout mode or in
the Sort mode.
Remove the new originals from the Document Processor and, once the
copy operation for the 2-in-1 or 4-in-1 layout mode or the Sort mode is
completed, reset them on the original table and try to copy again.
“E90” appears on the copy quantity/
magnification display
The copier’s memory is full.
To copy from those originals already scanned:
Press the Recall%/Enter key and copying will begin. Once those copies
have been made, reset the originals that have not yet been copied and
press the Start key. Copying will continue.
To start the copy procedure once again from the beginning:
Press the Stop/Clear key, set a lesser number of originals and try to copy
again.
“OP” appears on the copy quantity/
magnification display
The upper front cover or the front cover to the copier is open.
Close the covers securely.
“OP1” appears on the copy quantity/
magnification display
The left cover to the Document Processor is open.
Close the cover securely.
“J” and a number appear on the copy
quantity/magnification display
A paper jam has occurred.
Refer to “If paper jams” on page 8-3 and remove the jammed paper.
8-3
The Add Toner indicator lights The toner supply has run low.
Copying will still be available for awhile, but will then become impossible.
Replace the toner container as soon as possible.
9-2
The Add Toner indicator lights and “E33”
appears on the copy quantity/magnification
display
Toner has run out so further copying is impossible.
Replace the toner container.
9-2
“C” and a number appear on the copy
quantity/magnification display
Turn the power switch OFF ({) and then back ON ( | ) again. If the error
indication does not go out, make a note of the “C” and the number. Turn
the power switch OFF ({), remove the power cord, and contact your
service representative or an authorized service center.
“A” and a number appear on the copy
quantity/magnification display
Turn the power switch OFF ({) and then back ON ( | ) again. If the error
indication does not go out, make a note of the “A” and the number. Turn
the power switch OFF ({), remove the power cord, and contact your
service representative or an authorized service center.
Indication Procedure